Thyristor frequency converter has been reconstructed for the company of CPF Plzeň. Together with three-phase separating transformer and the load of oscillatory circuit it is used for induction heating of rod ends SOT 400/2,1.
The aim of the reconstruction was to increase the reliability of its operation and to change the frequency range from original 500 - 1500 Hz to 700 - 2100 Hz. During the reconstruction the current regulator SMK-UB with fifteen units was replaced by a new one containing four basic units with advanced integrated circuits CMOS. Also Programmable Logic Controller was added and water system including the thyristor coolers was changed.
Nominal input values (power circuits) | ||
Power Input [kVA] | 455 | |
Input voltage from separating transformer [V] | 3 x 400 | |
Frequency [Hz] | 50 | |
Nominal input values (control circuits) | ||
Power Input [kVA] | 3 | |
Voltage [V] | 3 x 400 | |
Frequency [Hz] | 50 | |
Cooling water (external cooling loop) | ||
Consumption [m3/h] | 4 | |
Input temperature [°C] | max. 30 | |
Input pressure [MPa] | max. 0,4 | |
Pressure loss [MPa] | 0,12 | |
Maximum warming thru loop [K] | 5 | |
Cooling water (internal cooling loop) | ||
System capacity [l] | 25 | |
Nominal output values | ||
Output [kW] | 400 | |
Nominal output voltage [V] | 600 | |
Frequency [kHz] | 0,7 - 2,1 | |
Ostatní parametry | ||
Dimensions (d x š x v) [mm] | 1800 x 800 x 2200 | |
Weight [kg] | 1800 | |
Cabinet | IP 43 | |
Color | - |