KOMPLETTE ANLAGEN FÜR INDUKTIONSERWÄRMUNG

Pyrometer UPF IV-G

Diese Serie wurde durch UPF V Pyrometer ersetzt.

The narrow-beam UPF IV-G radiation pyrometer with built-in galvanic isolation is a modernised version of the type UPF-IV pyrometer.   In more complex installations using the older version UPF IV pyrometer, is was necessary to use supply power with galvanic isolation.  With the new model IPF IV-G this issue is solved internally.  When considering that we were able to accomplish this without changing the overall dimensions of the pyrometer, electrical connections and output voltage waveform, the the new UPF IV-G can replace the older model without any additional modifications.  The benefits of the UPF IV-G pyrometer are appreciated by engineers in applications where there are issues with insufficient galvanic isolation on the analog inputs to a PLC.

The UPF IV-G pyrometer is designed for the non-contact measuring of molten and solid masses in metallurgy, forges, glassworks, coking plants, fireclay factories, hardening shops, wire works, chemical plants, engineering factories, and scientific laboratories. The temperature values can be processed by a programmable logic controller or a digital controller.

A pyrometer calibration certificate certifies accordance with national etalons corresponding to the international system of units (SI).

Technical parameters of the UPF IV-G pyrometer

UPF IV-G   1000 1200 1300 1400
Nominal temperature for ε = 1 [°C] 1000 1200 1300 1400
Measuring Range for ε = 1 [°C] 700 - 1000 800 - 1200 800 - 1300 900 - 1400
Nominal bearing distance L [m] 0,5 or 1,0   
Target Point Diameter D L=0,5m 
L=1,0m
[mm] 7
17 
4,7
11,2 
 3,6
8,5
 3,6
8,5
Bearing distance range [%] ± 50 ± 30 ± 25 ± 25
Output signal voltage UN [V] 0 - 10
Minimal Resistor Load R [Ω] 500
Voltage Output Table č.v. 4-909/005
% of Accuracy [%] 1
Spectral Sensitivity [μm] 0,8  - 1,1
Reaction Speed at Step Change [ms] 100
Operational Temperature -real
-max.
[°C] 45
55
Supply voltage UN [VDC] 22 - 36
Standby Current at UN=24VDC [mA] < 16
Weight L=0,5m
L=1,0m
[kg] 0,45
0,4
Dimensions Ø x 1 L=0,5m
L=1,0m
[mm] Ø40 x 321
Ø40 x 284

Notes:

  • When using different scanning distances that those listed, the diameter of the measuring point is always larger.
  • The presented reproducible accuracy applied to the upper-half of the range.

If necessary, these models can be supplied with modifications to various input voltages and/or different temperatures measuring ranges.

Tyto webové stránky využívají soubory cookies pro vylepšení funkcí webových stránek, analýze využívání webových stránek a cílení na návštěvníky stránek.